Ceramic Injection and Firing Furnace
€ 4500.00 excl. VAT
(SFr. 4410.00, £ 3870.00, $ 4725.00)
Shipping to
Request sent! Please check your email for further information.
Attention! The selling price does not include shipping costs!
The shipping and all related costs must be arranged between the buyer and the seller after the purchase.

Description

Dekema AUSTROMAT 354 press-i-dent oven - Ceramic Injection and Firing Furnace with pump in excellent condition.

Little used.

Always used in dental clinic.

 

AUSTROMAT 354 press-i-dent: 200 standard firing programs can be clearly displayed in the Program Manager and are available for individual adaptation. Additional programs are either archived in the integrated memory in sets of 200 programs each, or simply loaded from the DEKEMA DREAM database from the internet. At present, more than 60,000 firing programs are available from nearly every dental ceramics manufacturer. Additional memory expansion or simple data transfers are also possible through the USB interface. The unique user interface of the AUSTROMAT 354 press-i-dent can be operated using the large touchscreen as well as the integrated webtechnology on each PC or Mac in the network. A JAVA™ capable browser is all that is needed to contact the AUSTROMAT 354 press-i-dent through a freely adjustable IP address. By incorporating the furnace into the network environment, online diagnostics or updates are also possible. A backup and recovery function through the USB interface reliably protects against data loss. Of course, firing programs can be retrieved or read out through the USB interface. In addition, the program runs can be recorded on a USB stick or accessed via FTP online. The image viewer can also supply files via FTP or USB. These functions make it easy to connect to “digital dental laboratories.”

The high-resolution screen can graphically portray the firing process or show patient images. The menu-guided professional mode enables precise entry of the drying and cooling steps. When programming in standard mode, the user can access saved (integrated) cooling steps. The use of the automated press time function (familiar from the AUSTROMAT 3001 press-i-dent) minimizes the cooling time of the pressed ceramic in the furnace and offers increased reliability.

Both of the detailed and the comprehensive programming needs of dental technicians can be accommodated in classic mode. The absolutely unrestricted programming language from the legendary AUSTROMAT 3001and AUSTROMAT 3001 press-i-dent offers an up-to-date and comfortable way for inputting data. A QWERTZ keyboard on the large touch-sensitive screen can also be operated with a USB mouse. Firing and pressing cycles can be programmed in any sequence without any time limits. This absolutely unrestricted programming option enables the use of any and all firing and pressing techniques. For example, the vacuum can be released while maintaining a specific pressure, or different pressures can be used in a single procedure.

Professional ModeRangeIntervalUnit

Dry temperature (AUTODRY)80 to 2001°C

Start temperature/ preheating temperature100 to 7001°C

Drying time00:00 to 99:5900:01min:s

Closed time00:00 to 99:5900:01min:s

Preheating time00:00 to 99:5900:01min:s

Vacuum level0 to 10010%

Heat rate2 to 99 or max.1°C/min

Final temperature/ firing temperature100 to 12001°C

Holding time with/without vacuum00:00 to 99:5900:01min:s

Temperature rise/drop 22 to 99 or max.1°C/min

End/firing/cooling/relaxation temperature 2100 to 12001°C

Holding time with/without vacuum 200:00 to 99:5900:01min:s

Temperature rise/drop 32 to 99 or max.1°C/min

End/firing/cooling/relaxation temperature 3100 to 12001°C

Holding time with/without vacuum 300:00 to 99:5900:01min:s

Cooling temperature100 to 12001°C

Cooling time00:00 to 99:5900:01min:s

Relaxation temperature100 to 12001°C

Relaxation time00:00 to 99:5900:01min:s

 

Classic ModeRangeIntervalItem

Temperature in the firing chamber100 to 12001°C

Lift position0 to 91open to closed

Vacuum in the firing chamber0 to 910 to 100%

Time1 to 640001s

Pressure0 to 9110 to 300 N

PTA (Press Time Automatic)1 to 9110 to 90%

Press with/without vacuumindividually settable

Active cooling when the firing chamber is closed100 to 12001°C

Active cooling when the firing chamber is open100 to 12001°C

Acoustic signal1 to 91Number of tones

Temperature change rate1 to 991°C/min

Time-controlled temperature increase100 to 12001°C/time interval

Time-controlled lift movement0 to 91Lift position/time interval

… and much moreindividually settable

The proven DEKEMA AUTODRY function can be activated in all programming modes. The simulated measurement of the object temperature has been further refined and adapted to the needs of modern ceramics.

The controlled electromechanical feed of the innovative upward pressing system requires no extra connection for compressed air and opens up unique possibilities. For example, different shades (presently up to five) can be pressed simultaneously in a muffle ring in a single step (trixpress muffle system not included in the scope of delivery).

The closed insulating system enabled by the upward pressing movement guarantees outstanding firing results even in the high and low temperature range.

Using the traditional silver wire test yields superb repeatability. The maximum vacuum reliability of the AUSTROMAT 354 press-i-dent is a reflection of standard DEKEMA quality.

Press ModeRangeIntervalUnit

Start temperature/ preheating temperature100 to 9001°C

Final temperatur/ press temperature100 to 12001°C

Heat rate2 to 99 or max.1°C/min

PTA (Press Time Automatic)on/off

Press time00:20 to 99:5900:01min:s

Press level0 to 9110 to 300 N

 

Easy ModeRangeIntervalUnit

Dry temperature (AUTODRY)80 to 2001°C

Start temperature/ preheating temperature100 to 7001°C

Drying time00:00 to 99:5900:01min:s

Closed time00:00 to 99:5900:01min:s

Preheating time00:00 to 99:5900:01min:s

Vacuum level0 to 10010%

Temperature increase2 to 99 or max.1°C/min

Final temperature/ firing temperature100 to 12001°C

Holding period with/without vacuum00:00 to 99:5900:01min:s

Cooling temperature90% of end temperature

Cooling time00:00 to 99:5900:01min:s

Relaxation temperature65% of end temperature

Relaxation time00:00 to 99:5900:01min:s

Setup: Units, language, date, time, screen settings, network, general code, furnace ID, acoustic signal, drying temperature, heating settings, long-term readiness, lift settings, check program, cleaning firing, temperature calibration, seal tests, printer, quality management, diagnosis data, login data, back/recovery, FTP server login and many other functions.

DEKEMA AUTODRY: Simulates object temperature measurement and automatically regulates the distance between the firing chamber and the firing object with the vibration-free lift for precise drying and cooling phases.

Automatic self-test: Internal test routines seamlessly monitor the temperature while the program is running.

Check program: An automatic diagnostics routine is integrated for all system components to determine the service intervals.

Network: JAVA™ Technology for use via IE6, Firefox, Opera, Safari etc.; supports cable-connected devices with automated IP address (DHCP); FTP client/server; OPC server support (optional)

Connections: 1 USB, 1 Ethernet (RJ 45)

Content: AUSTROMAT 354 press-i-dent ceramic furnace, vacuum pump, operating instructions, tweezers, device cable

Technical data: 220-240 V, 110-120 V or 95-105 V, 50-60 Hz, max. 1450 W (incl. pump), 710 mm x 385 mm x 285 mm (HxWxD), 24.5 kg (without pump).

Return for this product is excluded
Would you like to know the shipping cost in advance?
Request an individual shipping quote for your country of destination! First select the country of destination in the drop-down list above.

How do you want to proceed?

How do you want to proceed?

How do you want to proceed?

Description

Dekema AUSTROMAT 354 press-i-dent oven - Ceramic Injection and Firing Furnace with pump in excellent condition.

Little used.

Always used in dental clinic.

 

AUSTROMAT 354 press-i-dent: 200 standard firing programs can be clearly displayed in the Program Manager and are available for individual adaptation. Additional programs are either archived in the integrated memory in sets of 200 programs each, or simply loaded from the DEKEMA DREAM database from the internet. At present, more than 60,000 firing programs are available from nearly every dental ceramics manufacturer. Additional memory expansion or simple data transfers are also possible through the USB interface. The unique user interface of the AUSTROMAT 354 press-i-dent can be operated using the large touchscreen as well as the integrated webtechnology on each PC or Mac in the network. A JAVA™ capable browser is all that is needed to contact the AUSTROMAT 354 press-i-dent through a freely adjustable IP address. By incorporating the furnace into the network environment, online diagnostics or updates are also possible. A backup and recovery function through the USB interface reliably protects against data loss. Of course, firing programs can be retrieved or read out through the USB interface. In addition, the program runs can be recorded on a USB stick or accessed via FTP online. The image viewer can also supply files via FTP or USB. These functions make it easy to connect to “digital dental laboratories.”

The high-resolution screen can graphically portray the firing process or show patient images. The menu-guided professional mode enables precise entry of the drying and cooling steps. When programming in standard mode, the user can access saved (integrated) cooling steps. The use of the automated press time function (familiar from the AUSTROMAT 3001 press-i-dent) minimizes the cooling time of the pressed ceramic in the furnace and offers increased reliability.

Both of the detailed and the comprehensive programming needs of dental technicians can be accommodated in classic mode. The absolutely unrestricted programming language from the legendary AUSTROMAT 3001and AUSTROMAT 3001 press-i-dent offers an up-to-date and comfortable way for inputting data. A QWERTZ keyboard on the large touch-sensitive screen can also be operated with a USB mouse. Firing and pressing cycles can be programmed in any sequence without any time limits. This absolutely unrestricted programming option enables the use of any and all firing and pressing techniques. For example, the vacuum can be released while maintaining a specific pressure, or different pressures can be used in a single procedure.

Professional ModeRangeIntervalUnit

Dry temperature (AUTODRY)80 to 2001°C

Start temperature/ preheating temperature100 to 7001°C

Drying time00:00 to 99:5900:01min:s

Closed time00:00 to 99:5900:01min:s

Preheating time00:00 to 99:5900:01min:s

Vacuum level0 to 10010%

Heat rate2 to 99 or max.1°C/min

Final temperature/ firing temperature100 to 12001°C

Holding time with/without vacuum00:00 to 99:5900:01min:s

Temperature rise/drop 22 to 99 or max.1°C/min

End/firing/cooling/relaxation temperature 2100 to 12001°C

Holding time with/without vacuum 200:00 to 99:5900:01min:s

Temperature rise/drop 32 to 99 or max.1°C/min

End/firing/cooling/relaxation temperature 3100 to 12001°C

Holding time with/without vacuum 300:00 to 99:5900:01min:s

Cooling temperature100 to 12001°C

Cooling time00:00 to 99:5900:01min:s

Relaxation temperature100 to 12001°C

Relaxation time00:00 to 99:5900:01min:s

 

Classic ModeRangeIntervalItem

Temperature in the firing chamber100 to 12001°C

Lift position0 to 91open to closed

Vacuum in the firing chamber0 to 910 to 100%

Time1 to 640001s

Pressure0 to 9110 to 300 N

PTA (Press Time Automatic)1 to 9110 to 90%

Press with/without vacuumindividually settable

Active cooling when the firing chamber is closed100 to 12001°C

Active cooling when the firing chamber is open100 to 12001°C

Acoustic signal1 to 91Number of tones

Temperature change rate1 to 991°C/min

Time-controlled temperature increase100 to 12001°C/time interval

Time-controlled lift movement0 to 91Lift position/time interval

… and much moreindividually settable

The proven DEKEMA AUTODRY function can be activated in all programming modes. The simulated measurement of the object temperature has been further refined and adapted to the needs of modern ceramics.

The controlled electromechanical feed of the innovative upward pressing system requires no extra connection for compressed air and opens up unique possibilities. For example, different shades (presently up to five) can be pressed simultaneously in a muffle ring in a single step (trixpress muffle system not included in the scope of delivery).

The closed insulating system enabled by the upward pressing movement guarantees outstanding firing results even in the high and low temperature range.

Using the traditional silver wire test yields superb repeatability. The maximum vacuum reliability of the AUSTROMAT 354 press-i-dent is a reflection of standard DEKEMA quality.

Press ModeRangeIntervalUnit

Start temperature/ preheating temperature100 to 9001°C

Final temperatur/ press temperature100 to 12001°C

Heat rate2 to 99 or max.1°C/min

PTA (Press Time Automatic)on/off

Press time00:20 to 99:5900:01min:s

Press level0 to 9110 to 300 N

 

Easy ModeRangeIntervalUnit

Dry temperature (AUTODRY)80 to 2001°C

Start temperature/ preheating temperature100 to 7001°C

Drying time00:00 to 99:5900:01min:s

Closed time00:00 to 99:5900:01min:s

Preheating time00:00 to 99:5900:01min:s

Vacuum level0 to 10010%

Temperature increase2 to 99 or max.1°C/min

Final temperature/ firing temperature100 to 12001°C

Holding period with/without vacuum00:00 to 99:5900:01min:s

Cooling temperature90% of end temperature

Cooling time00:00 to 99:5900:01min:s

Relaxation temperature65% of end temperature

Relaxation time00:00 to 99:5900:01min:s

Setup: Units, language, date, time, screen settings, network, general code, furnace ID, acoustic signal, drying temperature, heating settings, long-term readiness, lift settings, check program, cleaning firing, temperature calibration, seal tests, printer, quality management, diagnosis data, login data, back/recovery, FTP server login and many other functions.

DEKEMA AUTODRY: Simulates object temperature measurement and automatically regulates the distance between the firing chamber and the firing object with the vibration-free lift for precise drying and cooling phases.

Automatic self-test: Internal test routines seamlessly monitor the temperature while the program is running.

Check program: An automatic diagnostics routine is integrated for all system components to determine the service intervals.

Network: JAVA™ Technology for use via IE6, Firefox, Opera, Safari etc.; supports cable-connected devices with automated IP address (DHCP); FTP client/server; OPC server support (optional)

Connections: 1 USB, 1 Ethernet (RJ 45)

Content: AUSTROMAT 354 press-i-dent ceramic furnace, vacuum pump, operating instructions, tweezers, device cable

Technical data: 220-240 V, 110-120 V or 95-105 V, 50-60 Hz, max. 1450 W (incl. pump), 710 mm x 385 mm x 285 mm (HxWxD), 24.5 kg (without pump).

Return for this product is excluded

Questions and answers

Your message

Log in to send a message.

How do you want to proceed?

How do you want to proceed?

Similar products
WILL Wetzlar Mikroskop Laboratory Microscope Labormikroskop gepflegt GEPRÜFT
€ 439.00
MEDTRONIC 24950 MyCareLink
MEDTRONIC 24950 MyCareLink Patient
€ 69.99
Swelab alpha kap Coulter
Hämatologie Zählgerät
SFr. 350.00
Biomérieux Mini Vidas
Immuno Analyzer
€ 4500.00
Newsletters

TOP OFFER

Planmeca Quart DE Test Phantom Röntgenprüfkörper dent/digitest 3.1 NEU/OVP
€ 448.00

TOP OFFER

Headlamp/OP lamp
Snowden-Pence company xenon headlamp
SFr. 300.00

TOP OFFER

SONICAID BV105 ULTRASOUND TRANSDUCER Dual function vascular flow detector
£ 298.00
Shipping partners

Partners

Artikel nicht gefunden?

Artikel nicht gefunden?

What kind of equipment are you looking for?
Over 10.000 new and used devices from all medical fields

 

 

What specialty do you work in?
Find your new medical product easily based on your specialty