GE MAC 1200 Electrocardiograph ECG EKG with trolley and cables






GE MAC 1200 Electrocardiograph ECG EKG with trolley and cables
Description
TESTED FUNCTIONAL
Comes with its trolley, NEW ECG cables and PaperLast unit available !
FEATURES: The GE MAC 1200 is a digital 12-lead EKG Machine that offers comprehensive ECG solutions. The MAC 1200 offers practical features that help meet the demanding needs of hospitals, clinics, office-based practices, and clinical trials. Its advanced algorithm capabilities, seamless connectivity to the CS and MUSE Cardiology Information Systems and easy-t0-use features; provide maximum quality and convenience. Resting ECGs acquired in the 12-lead mode, and the corresponding data, can then be transmitted to a PC, CardioSys system, or to a MUSE CV system. This EKG Machine is equipped with electronic utilities that ensure artifact-free recordings. Among these are the automatic baseline adjustment and the anti-drift system (Cubic Spline and ADS).
This system can be configured to meet the needs of hospitals, clinics, and office-based practicesAllows access to EKG data gathered throughout a provider network, assuring high quality and continuity of careComprehensive solution for EKG requirementsWaveform LCD displayInterpretive EKGFull-size paper reportsPortable with a built-in batteryMeasurements, interpretation, and memory available in any combinationSimultaneous 12-lead ECG acquisition and analysisCompact, lightweight design with carrying handleField upgradability
Signal Processing:Acquisition: 12 leads – simultaneously.Signal input: Type CF according to IEC.Digital sampling rate: 1000 samples/second/channel.Dynamic range: Differential signals for AC voltage ±, 10mV Superimposed DC voltage (Polarization voltage) ±600mV.Resolution: 5 uV.Frequency response:0.04 – 150 Hz.Common mode rejection:> 140 dB.Input impedance: > 100 M ohms.Leakage current: < 10uA.Pacemaker detection sensitivity: All leads, duration 0.1 – 2.5 ms, amplitude > 5 mV.
Special Functions:Anti Drift System (ADS): Automatic compensation of baseline fluctuations caused by polarization voltage fluctuations at the electrodes.Baseline adjustment: ECG presentation on the averaged baseline.Electrode monitoring: Audible and visual indication on the LCD of disconnected electrodes or fine break. Every single electrode is monitored.Copy: In the automatic 12 lead modes, after ECG, recording, copies of the ECG can be printed.Test: Automatic performance test upon power up, including verification of the signal path starting at the signal input.International ShippingWe do our best to ship items the same day the payment has cleared, in some instances we are unable to. All items will be shipped within 1-4 working daysReturnsIf you are not 100% satisfied with your purchase, we have a 14-day money back guarantee policy. Excluding Items sold as-is / for parts only. Reimbursement for returns will be paid after the purchased item is returned. Free returns apply to damaged, broken and items not as described! Buyer is responsible for return shipping on items purchased accidentally or items no longer wanted/needed etc.We ship worldwide ! Please feel free to contact us for any question!






How do you want to proceed?
How do you want to proceed?
Description
TESTED FUNCTIONAL
Comes with its trolley, NEW ECG cables and PaperLast unit available !
FEATURES: The GE MAC 1200 is a digital 12-lead EKG Machine that offers comprehensive ECG solutions. The MAC 1200 offers practical features that help meet the demanding needs of hospitals, clinics, office-based practices, and clinical trials. Its advanced algorithm capabilities, seamless connectivity to the CS and MUSE Cardiology Information Systems and easy-t0-use features; provide maximum quality and convenience. Resting ECGs acquired in the 12-lead mode, and the corresponding data, can then be transmitted to a PC, CardioSys system, or to a MUSE CV system. This EKG Machine is equipped with electronic utilities that ensure artifact-free recordings. Among these are the automatic baseline adjustment and the anti-drift system (Cubic Spline and ADS).
This system can be configured to meet the needs of hospitals, clinics, and office-based practicesAllows access to EKG data gathered throughout a provider network, assuring high quality and continuity of careComprehensive solution for EKG requirementsWaveform LCD displayInterpretive EKGFull-size paper reportsPortable with a built-in batteryMeasurements, interpretation, and memory available in any combinationSimultaneous 12-lead ECG acquisition and analysisCompact, lightweight design with carrying handleField upgradability
Signal Processing:Acquisition: 12 leads – simultaneously.Signal input: Type CF according to IEC.Digital sampling rate: 1000 samples/second/channel.Dynamic range: Differential signals for AC voltage ±, 10mV Superimposed DC voltage (Polarization voltage) ±600mV.Resolution: 5 uV.Frequency response:0.04 – 150 Hz.Common mode rejection:> 140 dB.Input impedance: > 100 M ohms.Leakage current: < 10uA.Pacemaker detection sensitivity: All leads, duration 0.1 – 2.5 ms, amplitude > 5 mV.
Special Functions:Anti Drift System (ADS): Automatic compensation of baseline fluctuations caused by polarization voltage fluctuations at the electrodes.Baseline adjustment: ECG presentation on the averaged baseline.Electrode monitoring: Audible and visual indication on the LCD of disconnected electrodes or fine break. Every single electrode is monitored.Copy: In the automatic 12 lead modes, after ECG, recording, copies of the ECG can be printed.Test: Automatic performance test upon power up, including verification of the signal path starting at the signal input.International ShippingWe do our best to ship items the same day the payment has cleared, in some instances we are unable to. All items will be shipped within 1-4 working daysReturnsIf you are not 100% satisfied with your purchase, we have a 14-day money back guarantee policy. Excluding Items sold as-is / for parts only. Reimbursement for returns will be paid after the purchased item is returned. Free returns apply to damaged, broken and items not as described! Buyer is responsible for return shipping on items purchased accidentally or items no longer wanted/needed etc.We ship worldwide ! Please feel free to contact us for any question!