DRAGER Fabius GSGood conditionNo visible damage
Not Tested / As-isWith the O2 sensor and reusable canister / absorber
2 x Last Units Available
FEATURES: The Drager Fabius GS is an inhalation anesthesia machine used in an operating, induction, and recovery rooms. It can be used with O2, N2O, and AIR supplied by a medical gas pipeline system or have externally mounted gas cylinders. The Fabius GS is equipped with a compact breathing system that provides fresh gas decoupling, PEEP, and pressure limitation. This anesthesia machine has 5 main ventilation options that include; Volume Controlled Ventilation, Pressure Controlled Ventilation, Pressure Support, Manual Ventilation, and Spontaneous Breathing. It's equipped with an electrically driven and electronically controlled ventilator that monitors for airway pressure (P), volume (V), and inspiratory oxygen concentration (FiO2).
The Drager Fabius GS anesthesia machine is a popular choice for practitioners who demand advanced ventilation technology combined with reliable and proven breathing system components. The Fabius GS anesthesia workstation opens new frontiers in ventilation performance while maintaining well-established functionality.
High-performance ventilation with versatility that’s more flexible and economical to use than traditional gas-driven bellows ventilatorsFull-color screenCompact, convenient breathing system that's ergonomically designed for optimal positioningClinicalVision – monitoring solution that allows the caregiver to view patient monitoring and clinical data simultaneouslyCustomized design for flexibility and ease of useReady for IT-integrationLow-flow ventilationElectronic vertical flow controls and electronic fresh gas flow indicatorsIntelligent cable management for reduced clutter and easier patient transEasy integration into existing hospital information systemCentral brakingContinuous monitoring during transport and automatic reconfiguration of site-specific parameters with Dräger’s innovative Infinity Docking Stations (IDS).Drager Fabius GS Specifications
Rechargeable BatteriesRaitng: 24V; 3.5 AhType: Sealed, gelled lead-acidRecharge Time: ? 16 hours on the mains or full operation timeOperating time with fully charged batteries: 45 minutes, minimum
Ventilator Input RangesPMAX Pressure Limiting: 15 - 70 cmH2O (1 cmH2O resolution)VT Tidal Volume: 20 - 1400 mL (10 mL resolution)VT (SIMV/PS) Tidal Volume: 20 - 1100 mL (10 mL resoltuion)f Breathing Frequency: 4 - 60 bpm (1 bpm resolution)Ti/Te Inspiration/Expiration ration: 4:1 to 1:4Tip/Ti Inspiration pause: 0% - 50% (1% resolution)PEEP End-expiratory Pressure: 0 - 20 cmH2O (1 cmH2O resolution)Pinsp Inspiratory Pressure: 5 - 65 cmH2O (1 cmH2O resolution)Insp Flow Inspiratory Flow: 10 - 75 L/min (1 L/min resolution in Pressure Control Mode; 10 - 85 L/min (1 L/min resoltuion) in PS and SIMV/PS modes? PPS (Pressure Support) Support Pressure: 3 - 20 cmH2O (1 cmH2O resolution)? PPS (SIMV/PS) Support Pressur : 3 - 20 cmH2O, OFF (1 cmH2O resolution)Freq Min Apnea Ventialtion minimum frequency: 2 - 20 bpm (1 bpm resolution) and "OFF"Trigger: Trigger Level: 2 - 15 L/min (1 L/min resolution)Tinsp SIMV Inspiratory Time: 0.3 - 4.0 sec
Pressure Support Ventilation ModeEndotracheal Tube Size: 4.5 mm - 8 mmPatient Lung Compliance: 10 ml/cmH2O - 100 ml/chH2OUnassisted Patient Tidal Volume: 50 ml - 1000 mlPatient Breath Rate (BPM): 10 - 35Delivery AccuracyPmax Pressure Limiting: ±5 cmH2O of settingVT Tidal Volume: ± 5% of setting or 20 mL, whichever is greaterf Breathing Frequency: ±1 bpm of settingTi/Te Inspiration/Expiration Ratio: ±5% of settingTip/Ti Inspiration Pause: ±25% of settingPEEP End-expiratory Pressure: ±2 cmH2O or ±20% of setting, whichever is greater
Safety ReliefsHigh Pressure Safety Relief Valve: 75 ±5 cmH2ONegative Pressure Safety Relief Valve (Ambient Air Inlet Valve): -7.5 to -9 cmH2OSystem Compliance Compenstation Measurement: 0.2 to .0 ml/cmH2O: ±0.2 ml/cmH2O or ±10% of actual complaince, whichever is greater
Anesthesia Gas Supply ModuleFresh Gas Flow Indicators: O2, N2O, Air: Range and accuracy: 0.0 to 12.0 L/min ±10% of reading or 0.12 L/min (into an ambient atmosphere of 14.7 psi (101.3 kPa) at 20°C). Resolution: 0.1 L/minFresh Gas Flow Stability: O2 and N2O: ±10% of setting with pipeline pressures between 45 - 65 psi; Air ±10% of setting with pipeline pressures between 50 - 55 psi; Air flow rate will vary proportionally with supply pressures outside 50 - 55 psiTotal Fresh Gas Flowmeter: Range and accuracy: 0 to 10 L/min ±10% of full scale at STP, calibrated with 50% O2 / 50% N2O gas mixture; 0 to 10 L/min ±15% of full scale at STOP for all other gas mixtures; Resoltuion: 0.5 L/min from 0.5 - 2 L/min; 1.0 L/min from 2 - 10 L/minO2 Flush (bypass): at 55 psi (3.8 bar) max. 50 L/min; at 50 psi (3.4 bar) min. 35 L/minCommon Gas Outlet Pressure Limit: 13 psi (0.9 bar)
International ShippingWe do our best to ship items the same day the payment has cleared, in some instances we are unable to. All items will be shipped within 1-4 working daysReturnsIf you are not 100% satisfied with your purchase, we have a 14-day money back guarantee policy. Excluding Items sold as-is / for parts only. Reimbursement for returns will be paid after the purchased item is returned. Free returns apply to damaged, broken and items not as described! Buyer is responsible for return shipping on items purchased accidentally or items no longer wanted/needed etc.We ship worldwide !Please feel free to contact us for any question!We ship worldwide ! Please feel free to contact us for any question!






Wie möchten Sie fortfahren?
Wie möchten Sie fortfahren?
Beschreibung
DRAGER Fabius GSGood conditionNo visible damage
Not Tested / As-isWith the O2 sensor and reusable canister / absorber
2 x Last Units Available
FEATURES: The Drager Fabius GS is an inhalation anesthesia machine used in an operating, induction, and recovery rooms. It can be used with O2, N2O, and AIR supplied by a medical gas pipeline system or have externally mounted gas cylinders. The Fabius GS is equipped with a compact breathing system that provides fresh gas decoupling, PEEP, and pressure limitation. This anesthesia machine has 5 main ventilation options that include; Volume Controlled Ventilation, Pressure Controlled Ventilation, Pressure Support, Manual Ventilation, and Spontaneous Breathing. It's equipped with an electrically driven and electronically controlled ventilator that monitors for airway pressure (P), volume (V), and inspiratory oxygen concentration (FiO2).
The Drager Fabius GS anesthesia machine is a popular choice for practitioners who demand advanced ventilation technology combined with reliable and proven breathing system components. The Fabius GS anesthesia workstation opens new frontiers in ventilation performance while maintaining well-established functionality.
High-performance ventilation with versatility that’s more flexible and economical to use than traditional gas-driven bellows ventilatorsFull-color screenCompact, convenient breathing system that's ergonomically designed for optimal positioningClinicalVision – monitoring solution that allows the caregiver to view patient monitoring and clinical data simultaneouslyCustomized design for flexibility and ease of useReady for IT-integrationLow-flow ventilationElectronic vertical flow controls and electronic fresh gas flow indicatorsIntelligent cable management for reduced clutter and easier patient transEasy integration into existing hospital information systemCentral brakingContinuous monitoring during transport and automatic reconfiguration of site-specific parameters with Dräger’s innovative Infinity Docking Stations (IDS).Drager Fabius GS Specifications
Rechargeable BatteriesRaitng: 24V; 3.5 AhType: Sealed, gelled lead-acidRecharge Time: ? 16 hours on the mains or full operation timeOperating time with fully charged batteries: 45 minutes, minimum
Ventilator Input RangesPMAX Pressure Limiting: 15 - 70 cmH2O (1 cmH2O resolution)VT Tidal Volume: 20 - 1400 mL (10 mL resolution)VT (SIMV/PS) Tidal Volume: 20 - 1100 mL (10 mL resoltuion)f Breathing Frequency: 4 - 60 bpm (1 bpm resolution)Ti/Te Inspiration/Expiration ration: 4:1 to 1:4Tip/Ti Inspiration pause: 0% - 50% (1% resolution)PEEP End-expiratory Pressure: 0 - 20 cmH2O (1 cmH2O resolution)Pinsp Inspiratory Pressure: 5 - 65 cmH2O (1 cmH2O resolution)Insp Flow Inspiratory Flow: 10 - 75 L/min (1 L/min resolution in Pressure Control Mode; 10 - 85 L/min (1 L/min resoltuion) in PS and SIMV/PS modes? PPS (Pressure Support) Support Pressure: 3 - 20 cmH2O (1 cmH2O resolution)? PPS (SIMV/PS) Support Pressur : 3 - 20 cmH2O, OFF (1 cmH2O resolution)Freq Min Apnea Ventialtion minimum frequency: 2 - 20 bpm (1 bpm resolution) and "OFF"Trigger: Trigger Level: 2 - 15 L/min (1 L/min resolution)Tinsp SIMV Inspiratory Time: 0.3 - 4.0 sec
Pressure Support Ventilation ModeEndotracheal Tube Size: 4.5 mm - 8 mmPatient Lung Compliance: 10 ml/cmH2O - 100 ml/chH2OUnassisted Patient Tidal Volume: 50 ml - 1000 mlPatient Breath Rate (BPM): 10 - 35Delivery AccuracyPmax Pressure Limiting: ±5 cmH2O of settingVT Tidal Volume: ± 5% of setting or 20 mL, whichever is greaterf Breathing Frequency: ±1 bpm of settingTi/Te Inspiration/Expiration Ratio: ±5% of settingTip/Ti Inspiration Pause: ±25% of settingPEEP End-expiratory Pressure: ±2 cmH2O or ±20% of setting, whichever is greater
Safety ReliefsHigh Pressure Safety Relief Valve: 75 ±5 cmH2ONegative Pressure Safety Relief Valve (Ambient Air Inlet Valve): -7.5 to -9 cmH2OSystem Compliance Compenstation Measurement: 0.2 to .0 ml/cmH2O: ±0.2 ml/cmH2O or ±10% of actual complaince, whichever is greater
Anesthesia Gas Supply ModuleFresh Gas Flow Indicators: O2, N2O, Air: Range and accuracy: 0.0 to 12.0 L/min ±10% of reading or 0.12 L/min (into an ambient atmosphere of 14.7 psi (101.3 kPa) at 20°C). Resolution: 0.1 L/minFresh Gas Flow Stability: O2 and N2O: ±10% of setting with pipeline pressures between 45 - 65 psi; Air ±10% of setting with pipeline pressures between 50 - 55 psi; Air flow rate will vary proportionally with supply pressures outside 50 - 55 psiTotal Fresh Gas Flowmeter: Range and accuracy: 0 to 10 L/min ±10% of full scale at STP, calibrated with 50% O2 / 50% N2O gas mixture; 0 to 10 L/min ±15% of full scale at STOP for all other gas mixtures; Resoltuion: 0.5 L/min from 0.5 - 2 L/min; 1.0 L/min from 2 - 10 L/minO2 Flush (bypass): at 55 psi (3.8 bar) max. 50 L/min; at 50 psi (3.4 bar) min. 35 L/minCommon Gas Outlet Pressure Limit: 13 psi (0.9 bar)
International ShippingWe do our best to ship items the same day the payment has cleared, in some instances we are unable to. All items will be shipped within 1-4 working daysReturnsIf you are not 100% satisfied with your purchase, we have a 14-day money back guarantee policy. Excluding Items sold as-is / for parts only. Reimbursement for returns will be paid after the purchased item is returned. Free returns apply to damaged, broken and items not as described! Buyer is responsible for return shipping on items purchased accidentally or items no longer wanted/needed etc.We ship worldwide !Please feel free to contact us for any question!We ship worldwide ! Please feel free to contact us for any question!